Mixing Procedure
Mixing procedure of Line Guard (1) Shuzai and Kokazai of polymer cement emulsion are poured into a container. (2) The paints are mixed with a stirrer for about three minutes. (3) S Compound and C Compound are added little by little into the paint and mixed for about five minutes to get the uniform material.
Mixing Procedure of Pillar Coat (1) Shuzai and Kokazai of polymer cement emulsion are poured into a container. (2) The paints are mixed with a stirrer for about three minutes. (3) S Compound is added little by little into the paint and mixed for about five minutes. (Caution) In case of spraying, clear water is added for 1-1.5 litter for coordination of stickiness.
Test Results Chart A: Test results of Pillar Coat
*1 (40 degrees x 12 hours, 10 degrees x 12 hours) x 20 cycles
test items Test Results Method of tests basic characteristics Test of permeating water with a pressure 0.14 According to JIS A-1404 (display of the ratio of permeated water) Test of sucking water 0.57 According to JIS A-1404 (display of the ratio of sucked water) Test of attachment power 26kg/square cms adhesive strength test by the Architecture Laboratory of the Minstry of Construstion Test of strongness against bending 28kg/square cms According to JIS A-1404 Test of strongness against compression 150kg/square cms According to JIS A-1404 Test of strongness against abrasion 1.5kg/500 times Tabor abrasion tester Test of strongness against shock 50cm/1000g Du-Pont impact tester durability Water-proof test 24kg/square cms Test of attachment power by adhesive strength test by the Architecture Laboratory of the Minstry of Construction (permeated for two years) Weather-proof test 30kg/square cms Test of attachment power by adhesive strength test by the Architecture Laboratory of the Minstry of Construction (exposed in outdoors for two years) Weather-proof test for procedure More than 9H Hardness test of the pencil (weather-o-meter 1000hours) Stability test for freezing and dissolution 35kg/square cms Test of attachment power by adhesive strength test by the Architecture Laboratory of the Minstry of Construction *1 Durability test against salty water More than 9H Hardness test of the pencil (permeated for one month) Durability test against salty water More than 9H Hardness test of the pencil (permeated for one month) Durability test against alkali More than 9H Hardness test of the pencil (permeated for one month) Durability test against acid 3H Hardness test of the pencil (permeated for one month) Chart B: Elution Tests of Line Guard
Name of the tested material The number of the test Analyzed items Sn Cd As Pb PCB Hg Cu Line Guard K459 not detected
<0.1not detected
<0.002not detected
<0.02not detected
<0.01not detected
<0.0005not detected
<0.00050.08 Method of Line Guard measurement
*The unit is mg/l. The method of elution tests follow the Notice No.13 by the Environment Agency.
Sn JIS K 0102 63.1 Method of measuring briliantness Cd JIS K 0102 55.2 Method of measuring atomic briliantness As JIS K 0102 61.1 Method of measuring briliantness Pb JIS K 0102 54.2 Method of measuring atomic briliantness PCB Notice No.59 by the Environment Agency gas chromatographic analysis rules Hg Notice No.59 by the Environment Agency Method of measuring atomic briliantness Cu JIS K 0102 52.2 Method of measuring atomic briliantness
home next